Specification

IP rating: IP67 submersion rated (up to 1m for 30 minutes).

ATEX or IECEx are the certifications for IS products that achieve accreditation by Prevention

IECEx International Electro-technical Commission EXplosive certified safe.

  • IECEx is the worldwide standard
  • ATEX is the EU version of IECEx

The STP8X attains ATEX and IECEx certification through the use of Prevention techniques.

International IECEx Specifications

Gas Environment:

  • Protection by Intrinsic Safety: ib (one countable fault)
  • Gas Group: IIC (and all lower groups IIB and IIA)
  • Temperature: T4 (135 °C and all lower groups T3, T2 and T1)
  • Equipment Protection Level: Gb (Gas Zone 1 and 2)
    • Protection by Intrinsic Safety: ib (one countable fault)
    • Dust Group: IIIC (conductive dust and all lower groups IIIB and IIIA)
    • Equipment Protection Level: Db (Dust Zone 21 and 22)
    • Enclosure rated to:IP6x (Dust tight enclosure)

    European ATEX Specifications

    Gas Environment:

    • ATEX directive 94/9/EC
    • Equipment Group: II
    • Equipment Category: 2 (Suitable for use in Zone 1 and 2)
    • Protection by Intrinsic Safety: ib (one countable fault)
    • Gas Group: IIC (Hydrogen and the lower classes including; IIB – Ethylene; and IIA – Propane)
    • Temperature: T4 (135 °C and all lower groups T3, T2 and T1)
    • Equipment Protection Level: Gb (Gas Zones 1 and 2)

    Dust Environment:

    • Equipment Group: II
    • Equipment Category: 2 (suitable for use in Zone 21 and 22)
    • Protection by Intrinsic Safety: ib (one countable fault)
    • Dust Group: IIIC (conductive dust and all lower groups IIIB and IIIA)
    • Equipment Protection Level: Db
    • Enclosure rated to:IP6x (Dust tight enclosure)